Actions
Technical specifications¶
This page describes the hardware and electrical characteristics of the IOcan CAN gateway. Higher-level protocol support, transmission-specific behavior, and configuration details are documented on separate pages.
Power Supply and Electrical Characteristics¶
- Nominal operating supply voltage: 14.4 V
- Absolute maximum supply voltage: 18 V
- Maximum system current: < 20 A
- Internal fuse rating: 30 A
- Reverse polarity protection: Yes
- Wake-up voltage threshold: 4.5 V ± 0.3 V
The device is designed for permanent battery connection via fuse. Transmission power sequencing and wake-up behavior are managed internally.
⸻
CAN Interfaces¶
- Number of CAN interfaces: 4
- CAN controller and transceiver: MCP2558FD
- Supported standards:
- Classical CAN (CAN 2.0A / 2.0B)
- CAN FD
- Supported bitrates:
- Classical CAN: up to 1 Mbps
- CAN FD data phase: up to 8 Mbps
- Bitrate selection: Fully configurable
- Switchable 120 Ω termination on each CAN network
⸻
USB Interface¶
- Connector type: USB-C
- USB speed: 480 Mbps (USB 2.0 High Speed)
- USB function:
- Device configuration
- Data logging
- Diagnostics
- Configuration software: Dedicated IOcan configuration tool
- CAN data access:
- CAN traffic logging
- candump-compatible CAN output over USB
⸻
Inputs¶
- Total analog inputs: 11
- 7 inputs with 0–12 V range
- 4 inputs with 0–5 V range
- Frequency inputs: 4
- Shared with analog inputs
- Input usage:
- Sensor inputs
- Shifter inputs
- Button and switch inputs
- Custom user-defined signals
⸻
Outputs¶
- Transmission wake-up output: Dedicated
- Digital outputs: 5
- Maximum current per output: 0.9 A
- Outputs shared with analog input pins
- Transmission power output:
- Integrated semiconductor relay
- Rated current: 15 A
- Used for KL30B transmission power control
All transmission power control and wake-up signaling is handled directly by the device.
⸻
Connectors¶
- Main connector:
- TE Connectivity Superseal 1.0
- 26-pin, 2-row
Pin assignments and wiring details are documented in the Pinout section of the wiki.
⸻
Power Monitoring¶
- Transmission current measurement: Supported
- Purpose:
- System monitoring
- Diagnostics
- Safety and fault detection
⸻
Environmental and Mechanical Characteristics
- Physical dimensions: To be specified
- Weight: To be specified
Updated by Adam Klama 2 days ago · 1 revisions