Project

General

Profile

Actions

Technical specifications

This page describes the hardware and electrical characteristics of the IOcan CAN gateway. Higher-level protocol support, transmission-specific behavior, and configuration details are documented on separate pages.

Power Supply and Electrical Characteristics

  • Nominal operating supply voltage: 14.4 V
  • Absolute maximum supply voltage: 18 V
  • Maximum system current: < 20 A
  • Internal fuse rating: 30 A
  • Reverse polarity protection: Yes
  • Wake-up voltage threshold: 4.5 V ± 0.3 V

The device is designed for permanent battery connection via fuse. Transmission power sequencing and wake-up behavior are managed internally.

CAN Interfaces

  • Number of CAN interfaces: 4
  • CAN controller and transceiver: MCP2558FD
  • Supported standards:
    • Classical CAN (CAN 2.0A / 2.0B)
    • CAN FD
  • Supported bitrates:
    • Classical CAN: up to 1 Mbps
    • CAN FD data phase: up to 8 Mbps
  • Bitrate selection: Fully configurable
  • Switchable 120 Ω termination on each CAN network

USB Interface

  • Connector type: USB-C
  • USB speed: 480 Mbps (USB 2.0 High Speed)
  • USB function:
    • Device configuration
    • Data logging
    • Diagnostics
  • Configuration software: Dedicated IOcan configuration tool
  • CAN data access:
    • CAN traffic logging
    • candump-compatible CAN output over USB

Inputs

  • Total analog inputs: 11
    • 7 inputs with 0–12 V range
    • 4 inputs with 0–5 V range
  • Frequency inputs: 4
    • Shared with analog inputs
  • Input usage:
    • Sensor inputs
    • Shifter inputs
    • Button and switch inputs
    • Custom user-defined signals

Outputs

  • Transmission wake-up output: Dedicated
  • Digital outputs: 5
  • Maximum current per output: 0.9 A
  • Outputs shared with analog input pins
  • Transmission power output:
  • Integrated semiconductor relay
  • Rated current: 15 A
  • Used for KL30B transmission power control

All transmission power control and wake-up signaling is handled directly by the device.

Connectors

  • Main connector:
    • TE Connectivity Superseal 1.0
    • 26-pin, 2-row

Pin assignments and wiring details are documented in the Pinout section of the wiki.

Power Monitoring

  • Transmission current measurement: Supported
  • Purpose:
    • System monitoring
    • Diagnostics
    • Safety and fault detection

Environmental and Mechanical Characteristics

  • Physical dimensions: To be specified
  • Weight: To be specified

Updated by Adam Klama 2 days ago · 1 revisions