CAN Gateway Pinout » History » Revision 15
Revision 14 (Adam Klama, 01/09/2025 08:43 AM) → Revision 15/18 (Adam Klama, 01/09/2025 11:06 AM)
# CAN Gateway Pinout
Connector: 1473712-1 (TE Connectivity Superseal 1.0mm 26pos, 2 row version)
Terminals:
* 1-1437284-0 (16AWG-14AWG)
* 1437284-9 (20AWG-14AWG)
|Pin Name | Pin | Pin | Pin Name |
|-----------------|-----|-----|------------|
| KL30 IN | 1 | 14 | KL31 |
| KL30B OUT | 2 | 15 | KL15IN |
| PWR6/WAKEUP OUT | 3 | 16 | AN1/PWR1 |
| AN2/PWR2 | 4 | 17 | AN3/PWR3 |
| AN4/PWR4 | 5 | 18 | AN5/PWR5 |
| AN6 | 6 | 19 | AN7 |
| AN8/FREQ2 | 7 | 20 | AN9/FREQ1 |
| AN10/FREQ4 | 8 | 21 | AN11/FREQ3 |
| SENSOR5V | 9 | 22 | sGND |
| CAN1H | 10 | 23 | CAN1L |
| CAN2H | 11 | 24 | CAN2L |
| CAN3H | 12 | 25 | CAN3L |
| CAN4H | 13 | 26 | CAN4L |
# Pin description
Terminal names starting with KL are names according to [DIN 72552](https://en.wikipedia.org/wiki/DIN_72552)
## KL31
KL31 - return to battery- or chassis ground. This pin should be connected with wire of at least 1.5mm<sup>2</sup>
## KL30 IN
KL30 - constant battery+ This device is optimized for low power consumption in standby - 0.5mA - it is strongly recommended to keep this terminal on constant bat+ or delayed off.
This pin should be wired wit at least 1.5mm<sup>2</sup>
## KL30B OUT
KL30B - delayed off battery+. This pin is intended to power the transmission and is capable of supplying 15A.
## KL15IN
KL15 - Battery + through ignition switch. This pin should be connected with wire of 0.35mm<sup>2</sup>
## ANx - x between 1 and 7
ANx - Analog input capable of measuring voltages of up to 16V
## ANx - x between 8 and 11
ANx - Analog input capable of measuring voltages of up to 6V
## PWRy - y between 1 and 6
PWR1 - Low current power output capable with current rating of 0.9A
## FREQz - z between 1 and 4
FREQz - Inputs for speed signals
## sGND
sGND - this pin supplies ground, for all sensors connected to analog and frequency inputs.
## SENSOR5V
SENSOR5V - this pin supplies 5V to sensors connected to analog and frequency inputs.
## CANxL and CANxH - x between 1 and 4
This pin pairs are used to connect gateway to different CANbus networks.
Inside device there are 0805 pads for 120R resistor for termination.