BMW F Series Gear Selector Switch (GWS) Pinout » History » Version 3
Adam Klama, 07/15/2024 10:17 PM
| 1 | 1 | Adam Klama | # BMW F Series Gear Selector Switch (GWS) Pinout |
|---|---|---|---|
| 2 | |||
| 3 | | Pin | Function | |
||
| 4 | |-----|--| |
||
| 5 | | 1 | Drivelogic Button (DCT Only) | |
||
| 6 | | 3 | PT_CANL | |
||
| 7 | | 4 | PT_CANH | |
||
| 8 | | 5 | PT_CAN2L | |
||
| 9 | | 6 | PT_CAN2H | |
||
| 10 | | 7 | Wakup | |
||
| 11 | | 8 | KL31 | |
||
| 12 | | 10 | KL30B | |
||
| 13 | |||
| 14 | ## Pin description |
||
| 15 | ### PT_CAN/PT_CAN2 |
||
| 16 | Two canbus networks responsible for all communication with the transmission. |
||
| 17 | This two networks have to be connected to the Can Gateway and to the transmission. |
||
| 18 | |||
| 19 | Please note: |
||
| 20 | PT_CAN is not terminated within the shifter. |
||
| 21 | PT_CAN2 is internally terminated with 120R resisor. |
||
| 22 | |||
| 23 | ### Wakeup |
||
| 24 | 3 | Adam Klama | This terminal has to be connected to Wakeup out pin on Can Gateway. |
| 25 | 1 | Adam Klama | |
| 26 | ### KL30B |
||
| 27 | This terminal has to be connected to KL30B out on the Can Gateway. |
||
| 28 | **Please keep in mind that this is current carrying connection which has to be made with wire of 0.5mm<sup>2</sup>** |
||
| 29 | |||
| 30 | ### KL31 |
||
| 31 | This terminal is ground for the shifter. |
||
| 32 | **Please keep in mind that this is current carrying connection which has to be made with wire of 0.75mm<sup>2</sup>** |
||
| 33 | |||
| 34 | ## Connection variants |
||
| 35 | 2 | Adam Klama | ### 8HP shifter with 8HP transmission or DCT F series shifter with DCT F series transmission |
| 36 | 1 | Adam Klama | In case of connecting the shifter to compatible transmission, it is recommended to wire the shifter to both PT_CAN and PT_CAN2 interfaces. |
| 37 | In this case PT_CAN has to be terminated at the shifter end with 120R resistor. |
||
| 38 | |||
| 39 | 2 | Adam Klama | ### 8HP shifter with DCT F series transmission or DCT F series shifter with 8HP transmission |